Corrosion Resistant Electromagnetic Pulse Valve

    Payment Type: L/C
    Incoterm: FOB,CIF
Basic Info

Model No.Customized

Additional Info

Packagingcarton

TransportationOcean,Land

PortXingang China

Payment TypeL/C

IncotermFOB,CIF

Product Description
Installation method
Before use, check whether components are damaged during transportation.
Before installing, ventilate and clean up the sundries in the gas supply pipeline. When installing, pay attention to the direction of gas flow and whether the nozzle is correct.
All the O seals must be coated with suitable lubricants during installation.

There are three pins on the solenoid valve coil and a special plug, one of which has a "" symbol for grounding pins, and the user can decide whether to connect to the ground as required. Generally, when voltage is less than 36V, it will not be grounded. When it is larger than 36V, it should be grounded. The other two are coil power pins, which are connected to the terminals of the pulse injection controller and the terminals of the common line of the valve respectively. Pay attention to whether the voltage is in line with the requirements.

DMF Z-62S electromagnetic pulse valve

The deduster gas compartment (including the nozzle) is determined by the user. The capacity of the gas separator should meet the gas source that provides the stability of the Electromagnetic Pulse Valve. The inner wall of the gas tank should clean the stainless steel and other sundries. The gas compartment is not leaked, and it meets the requirements of the relevant safety.

The sealing part of the valve and the gas bag and the injection connecting pipe is suitable for -10 to 70 degrees Celsius. If a high temperature seal is needed, please note separately when ordering.

Working conditions:
When the electromagnetic pulse valve is used, the environmental conditions are very important, which is related to the normal and smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
1, according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, AC power supply is convenient to use.
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.

Electromagnetic pulse valve for dust removal
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
8, voltage specifications are preferred to AC220V.DC24V.
9, in the environment where relative humidity is high and water droplets are dripping, we should choose waterproof solenoid valves.
10, the rated current and power consumption should be selected according to the power supply capacity. Attention should be paid to the higher VA value when AC starting, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.