http://www.hrdustcollector.com
Home > Products > Dust Collector Fittings > Electromagnetic Pulse Valve > Inch Electromagnetic Pulse Valve

Inch Electromagnetic Pulse Valve

    Payment Type: L/C
    Incoterm: FOB,CIF
Basic Info

Model No.Customized

Additional Info

Packagingcarton

TransportationOcean,Land

PortXingang China

Payment TypeL/C

IncotermFOB,CIF

Product Description
The solenoid valve is a large type. The pulse valve is one of the kinds. It can be called the Electromagnetic Pulse Valve. The pulse valve can open the valve by one time. It does not need continuous electricity and closes the valve after the power break.

Its valve voltage is relatively small, one is DC voltage, 6V/12V24V.

1, pulse valve: by gas flow through gas resistance, gas capacity delay, the input long signal into the pulse signal valve type valve is controlled by a pilot valve such as electromagnetic or pneumatic, and can start and close a high pressure gas source to produce a pulse valve.

2, electromagnetic pulse valve: refers to the combination of solenoid valve, pilot valve and pulse valve, directly controlled by the electrical signal diaphragm valve.

DF-Y-40SY electromagnetic pulse valve

The solenoid valve is divided into the intake electromagnetic valve and the intake solenoid valve. In fact, the principle is the same, but the medium is different.

Working conditions:

When the electromagnetic pulse valve is used, the environmental conditions are very important, which is related to the normal and smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
1, according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, AC power supply is convenient to use.
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.

DMF Z-62S electromagnetic pulse valve
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
8, voltage specifications are preferred to AC220V.DC24V.

Right angle air solenoid valve
9, in the environment where relative humidity is high and water droplets are dripping, we should choose waterproof solenoid valves.
10, the rated current and power consumption should be selected according to the power supply capacity. Attention should be paid to the higher VA value when AC starting, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.

Product Categories : Dust Collector Fittings > Electromagnetic Pulse Valve

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Liuhuabing Mr. Liuhuabing
What can I do for you?
Contact Supplier