Botou Hengrui Environmental Protection Equipment Co. Ltd.
Installation of Pulse Solenoid Valve,Copper Body Solenoid Valve,Plastic Solenoid Valve
Model No.: Customized
Packaging: carton
Transportation: Ocean,Land
Port: Xingang China
Payment Type: L/C
Incoterm: FOB,CIF
The solenoid valve is only equivalent to the discharge of fluid. The pulse valve has a storage and release process. To make a metaphor, both the solenoid valve and the pulse valve are ventilated. The solenoid valve opens the gas and flows smoothly. And the pulsate valve is the blasting sound of the ejection belt.
Working pressure: Z type valve: 0.4~0.6Mpa
Type Y valve: 0.2~0.6Mpa ZM type valve: 0.4~0.6Mpa.
Air source medium: temperature <55 degrees C, by deoiling, water treatment, filtration accuracy <5 mu m adjustable pressure of clean gas.
Use of the environment:
1, temperature: -25 C ~55 C 55 C ~180 C.
2, the relative humidity of the air is not more than 85%.
3, the protection grade accords with IP64.
Diaphragm life: 1 million times.
Pulse valve life: standard installation, proper use and reasonable maintenance for five years.
Working conditions:
When the Electromagnetic Pulse Valve is used, the environmental conditions are very important, which is related to the normal and smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
1, according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, AC power supply is convenient to use.
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
8, voltage specifications are preferred to AC220V.DC24V.
9, in the environment where relative humidity is high and water droplets are dripping, we should choose waterproof solenoid valves.
10, the rated current and power consumption should be selected according to the power supply capacity. Attention should be paid to the higher VA value when AC starting, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.
Product Categories : Dust Collector Fittings > Electromagnetic Pulse Valve