Summary:
Electromagnetic Pulse Valve: a diaphragm valve that combines electromagnetic valve, pilot valve and pulse valve and is directly controlled by electrical signals.
The effect of electromagnetic pulse valve:
It is to control the oil pressure in the oil road. Generally installed in the main oil circuit or shock absorber back pressure oil circuit, to reduce the gear shift and lock the lock when the impact of oil pressure, so that the operation of the equipment to maintain a steady state.
According to the angle of valve inlet and outlet and the form of air inlet, it can be divided into three types.

A) right angle electromagnetic pulse valve: the diaphragm valve is directly angled by the electrical signal at the right angle of the inlet and outlet of the valve body.

Electromagnetic pulse valve for dust removal

B) straight through electromagnetic pulse valve: the diaphragm valve is directly controlled by electrical signals at 180 degrees of inlet and outlet of the valve body.
C) submerged electromagnetic pulse valve: diaphragm valve which is directly submerged by the valve inlet and is directly controlled by electrical signals.

In addition to the conventional three solenoid valves, there is also a large caliber ultra-low voltage electromagnetic pulse valve for rotary injection.

Working conditions:

When the electromagnetic pulse valve is used, the environmental conditions are very important, which is related to the normal and smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
1, according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, AC power supply is convenient to use.

DMF Z-62S electromagnetic pulse valve
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
8, voltage specifications are preferred to AC220V.DC24V.
9, in the environment where relative humidity is high and water droplets are dripping, we should choose waterproof solenoid valves.
10, the rated current and power consumption should be selected according to the power supply capacity. Attention should be paid to the higher VA value when AC starting, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.