http://www.hrdustcollector.com
Home > Products > Dust Collector Fittings > Electromagnetic Pulse Valve > TSF submerged electromagnetic pulse valve

TSF submerged electromagnetic pulse valve

    Payment Type: L/C
    Incoterm: FOB,CIF
Basic Info

Model No.Customized

Additional Info

Packagingcarton

TransportationOcean,Land

PortXingang China

Payment TypeL/C

IncotermFOB,CIF

Product Description

The structural characteristics of the straight through Electromagnetic Pulse Valve are that the air inlet and outlet centerline is in a straight line, so it is called the straight through valve, and its structure is shown in the diagram. The electromagnetic pulse valve diaphragm divides the pulse valve into two air chambers in front and back. When the compressed air is connected, the pulse valve is closed. The principle of opening action is the same as that of the right angle valve, but the flow direction of the air jet is shown as shown. The advantage of straight through pulse valve is that it is easy to install and is often used in air box pulse precipitator.

Working conditions:
When the electromagnetic pulse valve is used, the environmental conditions are very important, which is related to the normal and 

Electromagnetic Pulse Valve

smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
1, according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, AC power supply is convenient to use.
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.

High frequency diaphragm type solenoid valve
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
8, voltage specifications are preferred to AC220V.DC24V.
9, in the environment where relative humidity is high and water droplets are dripping, we should choose waterproof solenoid valves.
10, the rated current and power consumption should be selected according to the power supply capacity. Attention should be paid to the higher VA value when AC starting, and the indirect guided solenoid valve should be preferred when the capacity is insufficient.

Low pressure right angle solenoid valve

Product Categories : Dust Collector Fittings > Electromagnetic Pulse Valve

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Liuhuabing Mr. Liuhuabing
What can I do for you?
Contact Supplier